Before starting assembly, please carefully read the safety instructions, which can be found at the end of these assembly instructions. Before starting installation, please make sure that you use the latest assembly instructions.
The installation system should be designed and planned using the Alumero Solar.Pro.Tool software. Please refer to the project report, which you will receive from the Solar.Pro.Tool or from your Alumero sales partner, for the required materials and the positions and arrangement of the individual components. This data is calculated statically and is of great importance for the safe and flawless functioning of the system.
Before installation, the installer of the photovoltaic system must ensure that the given roof substructure is designed for the additional loads that arise.
These assembly instructions explain the assembly processes of the eponymous system, the attachment to the roof substructure and the installation of the modules.
In the case of sheet metal roofs, the modules are usually mounted vertically so that the support profiles are parallel to the ridge. Two carrier profiles per module row are used as standard.
ALUMERO photovoltaic systems are designed exclusively to accommodate PV modules. Any other use is considered improper use.
The system is designed exclusively to accommodate PV modules. Any other use is considered improper use.
Assembly may only be carried out by trained specialists. In particular, work on the roof covering should be carried out by a roofer.
If you have any further questions, please use ALUMERO's professional and comprehensive consulting service. Our competent civil engineers and construction technicians are happy to help you.
Usage:
Tiled roof, beaver tail, slate
Roof pitch:
10° - 65°
Connection:
Plate head screws
Module orientation:
vertical/horizontal
Maximum module field size:
12m length
Screw assembly:
MA8 (A2-70) - 15 Nm
M10 (A2-70) - 30 Nm
Measure and mark the positions of roof hooks on the roof according to the Solar.Pro.Tool project report.
Please also pay attention to the module clamping areas, which can be found in the installation instructions for the modules used.
Remove the marked roof tiles over the rafters.
Position the roof hook on the rafter so that it is in the wavy valley of the underlying tile.
The roof hook bracket must not rest directly on the underlying tile. Maintain a distance of 3-5 mm.
A distance of 3-5 mm must also be maintained in the horizontal direction from the roof tile.
If necessary, remove parts of the lip of the underlying roof tile with an angle grinder (diamond blade).
Optionally, the tile lying under the roof hook can be replaced with a replacement tile plate.
Align the roof hooks horizontally using a string and secure them in the rafters with 2 plate head screws. Make sure that there must be a screw in each row of holes.
Attention:
Please note: Mounted roof hooks must not be used as stepladders!
Ensure that the roof hook base plate is fully supported. You can make bumps with div. Balance shims. Use additional rafters or counter battens to ensure that the roof hook base plate is fully supported.
Re-cover the roof properly with the removed tiles. If necessary, prong out parts of the lip of the removed roof tile with an angle grinder (diamond blade). Pay attention to the tightness of the roof.
In the case of rafter insulation, the roof hook must be attached to the rafters with 2 “wood screws with fixing thread”. The wood screws must be anchored in the rafters by at least 60 mm.
The wood screws with fixing threads must be provided on-site.
Please note:
According to the ALUMERO Solar.Pro.Tool project report, measure the positions of the roof hooks on the roof and remove the roof tiles over the rafters.
Please also pay attention to the module clamping areas, which can be found in the installation instructions for the modules used.
Replace the roof tile lying under the roof hook with a sheet metal tile. Use 2 plate head screws to screw the roof hook into the rafters.
Re-cover the roof properly with the removed tiles, ensuring that the roof is tight.
Please note:
According to the ALUMERO Solar.Pro.Tool project report, measure the positions of the roof hooks on the roof and remove the roof tiles over the rafters.
Please also pay attention to the module clamping areas, which can be found in the installation instructions for the modules used.
If necessary, avoid the slate roof tiles and use the titanium zinc sheets provided for this purpose to ensure that the adjacent slate roof tiles are sealed. Use 2 plate head screws to screw the roof hook into the rafters.
Cover the roof properly and comply with the regulations of the German Roofing Trade.
Please note:
Install the support profiles horizontally, parallel to the ridge, with the correct side facing up onto the roof hook and tighten with a torque of 15 Nm.
Required if the width of the module field is greater than the length of the support profile.
Insert the profile connector halfway into the first support profile and then push the second support profile onto the profile connector.
Please note:
Press end caps into the wearer end with your hand.
Height-adjustable connection with quick assembly adapter
Connection with quick assembly adapter
Connection with hammer head screw and hexagon nut
Please note: Make sure that the support profiles are installed straight and tension-free. Tightening torque of the fixing screws: M8 15 Nm/M10 30 Nm.
Install the “base rail” support profile horizontally, parallel to the ridge with the correct side facing upwards and tighten with a torque of 15 Nm.
Insert the cross connector into the “base rail” and tighten with a torque of 15 Nm.
Please note: If the “base rail” carrier profiles are mounted vertically, parallel to the local corridor, the support profile fixing screw of the cross connector must always be oriented upwards towards the ridge.
Install the “modular rail” support profile vertically, parallel to the town, with the correct side facing upwards on the cross connector and tighten with a torque of 15 Nm.
Required if the width of the module field is greater than the length of the support profile.
Insert the profile connector halfway into the first support profile and then push the second support profile onto the profile connector.
Press end caps into the wearer end with your hand.
Please note:
According to the ALUMERO Solar.Pro.Tool project report, measure the positions of the roof hooks on the roof and remove the roof tiles over the rafters.
Please also pay attention to the module clamping areas, which can be found in the installation instructions for the modules used.
The AL13 X roof hooks are installed in the same way as described in the “Roof hooks” section. Mount the “base rail” carrier profile vertically, parallel to the town corridor with the right side up on the roof hooks and tighten the fixing screw with 15 Nm.
Insert the cross connector into the “base rail” and tighten with a torque of 15 Nm.
Please note: If the “base rail” carrier profiles are mounted vertically, parallel to the local corridor, the support profile fixing screw of the cross connector must always be oriented upwards towards the ridge.
Install the “module rail” carrier profile horizontally parallel to the ridge with the correct side facing up on the cross connector and tighten with a torque of 15 Nm.
It is recommended to mount the modules vertically in a cross-connection.
Please note:
info: With the AL13 X roof hook, it is also possible to mount the modules horizontally with single-layer rail mounting. Always pay attention to the module clamping areas, which can be found in the installation instructions for the modules used.
Start with the lowest row of modules. Place the first module on the carrier profiles and align them.
Click the Click end clamp slightly at an angle and push it towards the module frame.
Allen screw with a torque of 15 Nm tighten.
The presentation is exemplary and depicts the system, tending not to the profiles used.
Please note: The end clamps must be attached at least 20 mm from the end of the respective mounting profile.
Attention: When using end clamps with threaded plates, attention must be paid to the orientation. The threaded plate must be positioned transversely to the profile channel.
Place the Click center clamp on the frame of the previous module and click in at a slight angle. Push the module so that both modules are firmly in place.
Allen screw with a torque of 15 Nm tighten.
The last module in a series of modules with terminators, as before
described, assemble. Assembly of the remaining module rows analogously.
The presentation is exemplary and depicts the system, tending not to the profiles used.
Please note:
Module cables should not hang down or rest on the roof covering. Push the clip attached to the cable tie into a profile channel of the support profile. Use the cable tie to tie the cable together.
Remove the clip by sliding it laterally out of the profile channel.
Potential balancing between the individual plant components must be carried out in accordance with the respective country-specific regulations. One way of grounding the ALUMERO sheet metal folding roof system is shown below. Cable averages and overall grounding concept are not included in these instructions and must be calculated or prepared by the contractor in accordance with the applicable standards and guidelines. Professional grounding methods other than those listed here are also possible.
In each row of carrier profiles, insert a wire clamp into the lower profile channel of the carrier profile. Insert the aluminum wire into the wire clamp and secure by tightening the screw. In this way, connect all rows of modules to each other conductively.
Whether the modules need to be grounded is specified by the module manufacturer in the respective module data sheet. If so, the potential equalization of the modules can be created in the following way, recommended by ALUMERO:
To integrate the modules into potential equalization, you can use ALUMERO end and middle terminals with pins. The pins sit in the terminals, pierce the anodized layer of the module frames and thus conductively connect all module rows together.
All product images included in these assembly instructions are for illustrative purposes and are not true to scale. Subject to changes and errors!
The grounding/potential equalization is attached to the edge of a module field on a foot with a screw (max. M8). The components are not included.
We recommend that you read the following notes carefully as they are very important when using the product. Please also check the safety regulations for the other system components.
ALUMERO mounting systems are designed exclusively to accommodate PV modules. Any other use is considered improper use. Proper use also includes compliance with the instructions in these assembly instructions. ALUMERO is not liable for damage resulting from failure to comply with the assembly instructions, in particular the safety instructions, or from misuse of the product.
You should follow these instructions carefully when working on the PV system. Installation, commissioning, maintenance and repair may only be carried out by persons who are suitably qualified and authorized.
Please comply with the applicable regulations and safety instructions.
You must take these accident prevention regulations into account:
Please comply with the applicable regulations and safety instructions.
You must comply with the following DIN standards:
Work on Alumero Systematic Solutions GmbH's systems may only be carried out by authorized personnel. The operator of the plant has the following safety-related obligations:
The frame may only be assembled by persons with appropriate qualifications, manual skills and basic mechanical knowledge.
It must be ensured that the commissioned persons are able to assess the work assigned to them and identify potential hazards. The assembly instructions are part of the product and must be available during installation.
The assembly instructions are part of the product and must be available during assembly.
It must be ensured that the installation instructions and in particular the safety instructions are read and understood by authorized personnel before installation.
The regulations of the professional association, local occupational safety regulations and technical rules must be complied with.
Suitable hoists and ladders must be used for installation. Staff ladders must not be used.
It is necessary to have the existing building statics checked by an expert civil engineer with regard to the additional loads from a PV system.
Any general load limits imposed by Alumero Systematic Solutions GmbH (e.g. the need to remove snow to limit the snow load) must be taken into account.
The sizing instructions contained in these instructions are only practical tips. Binding assembly frame statistics can be created with the Alumero Solar.Pro.Tool program.
As an installer, you are responsible for the correct installation. Alumero Systematic Solutions GmbH is not liable for the sizing instructions contained in commercial plant offers.
As an installer, you are responsible for the mechanical durability of the assembled interface connections on the building envelope, in particular for their tightness. The components of Alumero Systematic Solutions GmbH are designed for this purpose in accordance with the expected loads and the current state of the art. To do so, as part of the request/order to Alumero Systematic Solutions GmbH, you must provide all general technical conditions in the project data sheet (information on the supporting structure, snow load zone, building heights, wind loads, etc.) in writing.
Alumero Systematic Solutions GmbH is not liable for improper handling of the installed parts.
To prevent corrosion, the aluminum structure must only come into contact with media (solid, liquid, gaseous) that have a pH of 4.5 to 8.5.
With proper handling, dimensioning in accordance with static conditions and normal environmental and environmental conditions, Alumero Systematic Solutions GmbH provides a 2-year product warranty on the lifetime and durability of the frame systems. This applies within the framework of generally prevailing weather and environmental conditions.
Material and workmanship guarantee: Alumero Systematic Solutions GmbH provides a material and workmanship guarantee of 10 years on the materials used. For more information, please see the separate warranty conditions.
You may only carry out all electrical work if you are a qualified electrician. The applicable DIN standards, VDE regulations, VDEW guidelines, VDN guidelines, accident prevention regulations and the regulations of local electricity supply companies (EVU) are decisive.
Solar modules generate electricity as soon as they are exposed to light and are therefore always under voltage. Although the fully insulated plug contacts provide protection against contact, you must pay attention to the following when handling the solar modules:
High contact voltages can occur in the inverter even when switched off:
All standards and guidelines listed have been published and applied for Germany. They must be considered in their current version. Outside of Germany, please also comply with the relevant national standards and guidelines.
For installation in the roof area, you must comply with the currently valid rules of construction technology, in particular the requirements set out in the DIN standards and in the “German Roofing Trade Rules”.
The technical documentation is part of the product. Alumero Systematic Solutions GmbH is not liable for damage resulting from failure to comply with the assembly instructions, in particular the safety instructions, or from misuse of the products.